Cara mengatasi BlackBerry mati total (matot) dan nuked!!
Jika BlackBerry sobatt sedang trouble, mungkin beberapa langkah pengerjaan dibawah ini bisa membantu:
Dari berbagai kasus yang terjadi pada
BlackBerry, seperti
bold
9000, gemini 8250, aries 8350, curve 8320, javelin 8900, pearl 3G 9105,
davis 9220, armstrong 9320, curve 9300 3G, apollo 9360, 9370 – 9380,
storm 9500, strom2 9550, tour 9630, essex 9650, onyx 9700, onyx2 9780,
bellagio 9790, torch 9800, 9810, monza 9860, 9850, dakota 9900, montana
9930,
Porsche Design P’9981 dll. ternyata permasalahan yang juga sering didapat adalah BB dalam
kondisi mati total (matot) dan hanya led yang kedip-kedip merah atau hidup loading sebentar terus restart lagi
atau juga malah tidak ada tanda – tanda kehidupan sama sekali. Kasus
ini ada dua kemungkinan bisa karena software bisa juga karena hardware.
1. Sebelum sobatt melangkah lebih jauh,
jika BB tidak ada tanda – tanda kehidupan sama sekali.. maka pastikan
dulu battery Blackberry dalam kondisi bagus dan terisi full, ukur dengan
multitester jika punya, catu daya sekitar -+ 4v atau bisa pinjam
battery BB teman yang sama dan coba hidupkan di BB sobatt, apakah bisa
hidup?? coba dengan melepas simcard dan mmc serta battery -+ 5menit
setelah itu coba pasang kembali.
2. Jika usaha demikian belum
berhasil, itu artinya permasalahan ada di software atau hardware (ic
power, ic zocus, ic flash, ic cpu atau komponen lain).
3. Maksimalkan dulu ke software, coba dengan reload OS.
Jika kondisi ketika blackberry dinyalakan, lampu LED menyala merah untuk
beberapa detik, kemudian akan terlihat layar putih dan jam pasir dan
kemudian kembali mati, kemudian setelah beberapa detik blackberry akan
menyala lagi, proses booting ini berulang terus maka keadaan demikian
disebut “nuked”.
Atau BB hanya kedip-kedip lampu led merahnya
Untuk penyelesaiannya bisa dicoba dengan instal ulang / reload OS
Prosedur:
- Instal program desktop manager dan firmware BlackBerry yang akan di reload os
- Browse ke folder AppLoader menggunakan explorer, biasanya terletak
di C:\Program Files\Common Files\Research In Motion\AppLoader kemudian
delete file vendor.xml di dalam direktory AppLoader
- Jalankan Program loader.exe di dalam direktory >> C:\Program
Files\Common Files\Research In Motion\AppLoader>> double klik
loader.exe
- Klik Next sampai ada dialog “Communication Port Selection”
- Pasang Kabel USB yang sudah terhubung BB ke PC
- Klik Next, ulangi beberapa kali bila perlu sampai proses install OS dapat berjalan
4. Kode kedipan lampu LED pada saat awal loading menunjukkan suatu nilai biner yang menginformasikan pesan dari bootROM.
biner 1, nyala kedip lampu merah sedangkan biner 0 dengan tidak nyalanya
led (off). Apabila led menyala secara kontinyu, ini merupakan pesan
sedang melakukan security wipe, apabila led menyala kontinyu tidak pada
saat melakukan security wipe, ini mengindikasikan adanya kerusakan
hardware.
- 1 (desimal = 1) Bukan problem, kode ini adalah normal saat restart
- 11 (desimal = 3) Tidak ada sistem operasi di dalam blackberry, lakukan reload sistem operasi dengan MFI
- 101 (desimal = 5) Bad OS CRC
- 111 (desimal = 7) Missing OS CRC
- 1011 (desimal = 11) Missing OS Trailer
- 1101 (desimal = 13)OS Not Signed, coba loading OS kembali
- 1111 (desimal = 15) OS Signature Invalid, coba loading kembali OS
dan biarkan mati tanpa baterai selama hampir 30 menit, kemudian coba
hidupkan kembali. Apabila tetap muncul pesak kesalahan, coba lakukan
penggantian flash.
- 10101 (desimal = 21) Unknown Flash Manufacturer, coba lakukan penggantian flash
- 10111 (desimal = 23) Flash Initialization Problem, coba lakukan penggantian flash
- 11011 (desimal = 27) Flash Erase Failure ,coba lakukan penggantian flash
- 11101 (desimal = 29) Flash Operation Out Of Range
- 11111 (desimal = 31) Bad BootROM CRC, coba lakukan penggantian flash
- 101011 (desimal = 43) USB Driver Error
- 101101 (desimal = 45) No BootROM CRC
- 101111 (desimal = 47) Flash Write Failure, coba lakukan penggantian flash
- 110101 (desimal = 53) Invalid Memory Configuration Table
- 110111 (desimal = 55) Password Not Initiated
- 111011 (desimal = 59) RAM Initialization Problem, coba lakukan penggantian flash
- 111101 (desimal = 61) Cache No Pages Free
- 111111 (desimal = 63) Cache Invalid Page Type
- 1010101 (desimal = 85) Random Number Failure
- 1010111 (desimal = 87) OSStore Failure
- 1011011 (desimal = 91) Security Init Failure
- 1011101 (desimal = 93) NAND failure
- 1011111 (desimal = 95) General Assert Failure
- 1101011 (desimal = 107) GPIO failure
- 1101101 (desimal = 109) Runtime library failure
- 1101111 (desimal = 111) Exception: undefined isntruction
- 1110101 (desimal = 117) Exception: SWI
- 1110111 (desimal = 119) Exception: Prefetch Abort
- 1111011 (desimal = 123) Exception: Data Abort
- 1111101 (desimal = 125) Exception: Reserved
- 1111111 (desimal = 127) Exception: IRQ
- 10101011 (desimal = 171) Exception: FIQ
JVM Error Code
- 101 Internal JVM error.
- 102 Invalid code in file system. The .cod files in the handheld
have been checked for modification and it has been determined that there
is a problem with one or more .cod files.
- 103 The starting address for the boot .cod file cannot be found.
This might mean that a boot .cod file has not been installed on the
handheld, or that its format is invalid or corrupt.
- 104 An uncaught Java exception was thrown in the Java code and
diagnosed by the JVM. Execution can be continued or the handheld can be
attached to a debugger on a desktop through a serial or USB cable. The
event log should contain the traceback of the thrown exception.
- 105 An OS file system API returned an error status for a certain
operation. This can indicate a corrupt file system or an error in the
JVM.
- 106 An error has been detected in the graphics system of the handheld.
- 107 Internal JVM error.
- 108 Internal JVM error.
- 109 Internal OS error.
- 110 Non-idle event downtime error. A problem has been detected
in the accumulation of JVM down time that represents how long the JVM
has been idle. This indicates an error in either the OS code or the JVM
code.
- 200 Application manager threw an uncaught exception. The
application manager event thread threw an uncaught exception and so
cannot continue running.
- 201 Initialization of the cryptographic system failed and the handheld cannot continue to operate.
- 202 An attack on the key store has been detected, and the handheld cannot continue to operate.
- 203 The application manager console process, usually the Home screen ribbon, has failed, like due to an uncaught exception.
- 501 Internal error.
- 502 All processes exited. The last Java process has terminated, and there is nothing left to execute.
- 503 Internal error.
- 504 Internal error.
- 505 Internal error.
- 506 An uncaught Java exception was thrown in the initial VM Java
thread thus killing the only live thread in the system. The event log
contains the traceback for the exception.
- 507 A dependency on a .cod file could not be satisfied due to a
missing .cod file. Load the missing .cod file onto the handheld.
- 508 Invalid object. A problem has been detected with a debugger command to the VM.
- 516 Error occurred during garbage collection, which might indicate a corrupted file system.
- 510 All threads are waiting on objects, which results in a
deadlock. The system cannot recover from this state since no thread can
release a lock.
- 511 A problem has occurred during debugging.
- 515 The reachable objects form a group that cannot be
represented properly by the VM because there are too many objects or the
total size of the objects is too large.
- 516 When committing a persistent object, the VM found that the
persistent store id counter has reached its limit. The object was not
committed.
- 517 An inconsistency has been detected in the VM persistent object store.
- 518 Internal error.
- 519 Internal error.
- 520 Internal error.
- 521 Indicates that Object.wait() has been executed by a thread
that holds a lock on another object; occurs only in simulator if the
JvmDebugWaits application switch.
- 522 A thread has acquired two locks on objects in an order that
doesn’t match the order that previous locks for the two types were
acquired, which indicates a future potential deadlock situation;
reported only in the simulator when the JvmDebugLocks application switch
is set.
- 523 A critical Java process has died and the device cannot continue to operate normally.
- 524 An object has been marked as recovered by the Low Memory
Manager but it was not freed during a garbage collection. This is only
checked in the simulator under the control of the JvmDebugLMM
application switch.
- 525 Bad persistent object. An auto-commit operation during a
garbage collection has detected a non-persistent object reachable from
the pers
Semoga bermanfaat